Item | Specification | |||||||||||||||
Applicable Motor (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |
Type | VFPS1- | |||||||||||||||
Form | 4007PL | 4015PL | 4022PL | 4037PL | 4055PL | 4075PL | 4110PL | 4150PL | 4185PL | 4220PL | 4300PL | 4370PL | 4450PL | 4550PL | 4750PL | |
Output Capacity (kVA) | 1.8 | 3.1 | 4.4 | 8.0 | 11 | 13 | 21 | 25 | 31 | 37 | 50 | 60 | 72 | 88 | 122 | |
Rating | Output Current (A) | 2.3 | 4.1 | 5.8 | 10.5 | 14.3 | 17.6 | 27.7 | 33 | 41 | 48 | 66 | 79 | 94 | 116 | 160 |
2.3 | 4.0 | 5.3 | 8.6 | 13 | 17 | 25 | 32 | 37 | 38 | 53 | 60 | 75 | 93 | 120 | ||
Output Voltage | 3-phase, 380 to 480 V (The maximum output is the same as the input voltage.) | |||||||||||||||
Overload Current Rating | 120%-1 minute 135%-2 seconds | |||||||||||||||
Braking | Dynamic Braking Circuit | Built-in | ||||||||||||||
Electric | Dynamic Breaking Resistor | External options | ||||||||||||||
Supply | Voltage / Frequency | 3-phase, 380 to 480 V -50/60 Hz | ||||||||||||||
Power | Allowable Fluctuation | Voltage +10% to 15% Frequency ±5% | ||||||||||||||
Protective Method | IP20 enclosed type (JEM 1030) | IP00 enclosed type (JEM1030) | ||||||||||||||
Cooling Method | Forced air cooling | |||||||||||||||
Cooling Fan Noise (dBA) | 4 | 43 | 43 | 55 | 56 | 56 | 58 | 60 | 60 | 60 | 64 | 64 | 64 | 64 | 64 | |
Color | RAL7016 | |||||||||||||||
Built-in Filter | EMI noise filter | |||||||||||||||
DC Reactor | External Option | Built-in |